Product Overview
Hot water is not something we give much thought to on a daily basis. We know when we turn on the shower, hot water will come out and steam will be filling our bathroom shortly! Until the day it doesn't! A conventional storage tank water heater will last only about 10 to 15 years. You do not want the cold water of a morning shower to be your wake up call! Once you decide to replace your water heater, you don't have to think about it again for several years down the road.
With the ability to vent horizontally or vertically using 2" or 3" PVC, ABS or CPVC pipe, you can vent this hot water heater through the wall or through the roof. The Bradford White TTW1 models are power vented for positive exhaust.
The Bradford White Defender Safety System is designed to be the safest, most reliable flammable vapor ignition resistant system in the industry meeting all the requirements set forth by the American National Standards Institute (ANSI). The Defender Safety System features ScreenLok Technology flame arrestor. The louvered flame arrestor design increases the speed of incoming combustion air and creates a vector effect inside the combustion chamber when flammable vapors are ignited, preventing flames from traveling back through the flame arrestor and outside the water heater. Other features include Resettable thermal switch, virtually maintenance free.
ICON Control System is included on all Bradford White Residential and Light Duty Commercial Water Heaters. Features of the ICON System include:
Vitraglas® The World's Best Enamel Tank Lining: Bradford White water heater tanks are protected from the corrosive effects of hot water by an exclusive enamel lining. The exclusive Vitraglas enamel lining is uniquely formulated and applied to the interior of the water heater tank.
Our test results prove that Vitraglas provides unsurpassed protection against failure when compared to other water heater linings.
The Bradford White RG2PV40S6N is in compliance with the new Energy Factor requirements for water heater manufacturers set forth by the National Appliance Energy Conservation Act (NAECA).
With the ability to vent horizontally or vertically using 2" or 3" PVC, ABS or CPVC pipe, you can vent this hot water heater through the wall or through the roof. The Bradford White TTW1 models are power vented for positive exhaust.
The Bradford White RG2PV40S6N is a 40 gallon, short, hot water heater. A shorter tank height means a wider diameter. This tank is 55-5/16" from the floor to the top of the blower and the jacket diameter is 22" wide. Featuring an input of 40,000 BTUs, this hot water heater has a First Hour Rating or First Hour Delivery of 75 gallons.
Basically, the First Hour Rating means how much hot water the hot water heater can deliver in an hour of use, starting with a fully heated tank. It does not mean that the hot water will last for one hour. As the cold water enters the tank it is heated, the faster you use your hot water, the faster your water will become tepid and then cold. However, depending on your temperature set point and your household's water use you can calculate how much hot water you need during your busiest hour. As you use the water in the tank, it is continuously being replenished and heated.
The Uniform Energy Factor (UEF) is used to determine the energy efficiency of the hot water heater. Recover efficiency, stand-by loss and cycling loss are all included in the energy factor. Typically, the higher the energy factor, the more efficient the water heater. Cost of fuel however, will have an impact on annual operating costs.
An example of a 73 gallon peak demand might look like this:
- 4 showers (10 x 4 = 40 gallons)
- 1 bath (15 x 1 = 15 gallons)
- 1 meal prep (4 x 1 = 4 gallons)
- 2 hand dishwashings (4 x 2 = 8 gallons)
- 1 dishwasher run (6 x 1 = 6 gallons)
This household would probably want a hot water heater with a first hour rating of between 71 and 75 gallons.
Another important feature when choosing a hot water heater is the Recovery Rise. A 90° recovery rise for this tank is about 43 gallons per hour. All Bradford White hot water heaters are NAECA Compliant.
The Bradford White Defender Safety System is designed to be the safest, most reliable flammable vapor ignition resistant system in the industry meeting all the requirements set forth by the American National Standards Institute (ANSI). The Defender Safety System features ScreenLok Technology flame arrestor. The louvered flame arrestor design increases the speed of incoming combustion air and creates a vector effect inside the combustion chamber when flammable vapors are ignited, preventing flames from traveling back through the flame arrestor and outside the water heater. Other features include Resettable thermal switch, virtually maintenance free.
ICON Control System is included on all Bradford White Residential and Light Duty Commercial Water Heaters. Features of the ICON System include:
- Advanced Temperature Control System - A microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels
- Exclusive Performance Software
- Intelligent Diagnostics for installers with status indicator
- Pilot-On-Indication
- Millivolt Powered - No external electricity required
- Separate Immersed Thermowell - No need to drain the tank when removing or replacing the gas valve
- Integrated Piezo Igniter
Vitraglas® The World's Best Enamel Tank Lining: Bradford White water heater tanks are protected from the corrosive effects of hot water by an exclusive enamel lining. The exclusive Vitraglas enamel lining is uniquely formulated and applied to the interior of the water heater tank.
Our test results prove that Vitraglas provides unsurpassed protection against failure when compared to other water heater linings.
The Bradford White RG2PV40S6N is in compliance with the new Energy Factor requirements for water heater manufacturers set forth by the National Appliance Energy Conservation Act (NAECA).
- Standard Features:
- Advanced ScreenLok® Technology Flame Arrestor design
- Resettable thermal switch
- Maintenance free
- Pedestal base
- Sight window
- Powerful blower motor
- Factory installed Hydrojet® Total Performance System - Cold water inlet sediment reducing device helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up in tank.
- 2" Non-CFM Foam Insulation
- ICON Features:
- Enhanced Performance
- Advanced Temperature Control System
- Intelligent Diagnostics
- Pilot On Indication
- Green LED
- Separate Immersed Thermowell
- Power Venting - venting can be horizontally, through the wall or vertically, through the roof
- Dimensions:
- A - Floor to Top of Blower: 55-7/16"
- B - Jacket Dimensions: 22"
- C - Vent Size: 2" or 3"
- D - Floor to T&P Connection: 40-1/8"
- E - Floor to Gas Connection: 11-1/2"
- F - Floor to Top of Heater: 47-3/16"
- G - Floor to Water Connection: 49"
- H - Depth: 27-3/16"
This water heater is not certified for commercial use in Texas, or residential use in Utah, or the following air quality districts in California:
- Bay Area AQMD (Reg 9, Rule 6)
- Sacramento Metropolitan AQMD (Rule 411)
- San Joaquin Valley APCD (Rule 4902)
- Santa Barbara County APCD (Rule 352)
- South Coast AQMD (Rule 1146)
- Ventura County AQMD (Rule 74-11)
- Yolo-Solano AQMD (Rule 2.37)
Tech Specs
General Features
Weights and Dimensions
Performance
Venting and Connection Requirements
Electrical Requirements
California residents see Prop 65 WARNINGS
WARNING!
Warning: Cancer and Reproductive Harm - www.p65warnings.ca.gov