Empire Comfort Systems FAW-40-IPX 40,000 BTU Counterflow Vented Wall Furnace

Sku:
EMPIRE-FAW40IPX
Special Order - No Cancellations - No Refunds - Estimated Lead Time for NG 8 - 10 Weeks; Propane Usually Leaves Warehouse 2 - 3 Business Days
$2,659.00
Interior or exterior wall installation for the FAW40IPX wall furnace are both possible. Venting of this unit is up and through the roof. Interior installation options include flush on the wall or recessed between standard wall studs.
 
The FAW-40-IPX has an electronic ignition. A thermostat is not included with this furnace. This is a 24V furnace and can be used with either a Wireless Remote Wall Thermostat (TRW) or a Wall Thermostat Millivolt Reed Switch (TMV) [each sold separately].
 
Venting required:
  • Size of Flue Collar: 4" Oval
  • Size of Flue with Oval to Round Adapter: 4" Round
  • Minimum Vent Opening in Ceiling:
    • Oval Type "B" Flue Pipe: 4-1/2" x 9-1/4"
    • Round Type "B" Flue Pipe: 6.5" diameter
Counterflow wall furnaces heat larger areas and use a minimum amount of floor space. Heat comes out at floor level and rises, giving you an even heat distribution. The optional side (SOK-1) and rear (ROK-1) accessory outlet kits allow heat to disperse from side or the rear of the furnace to an adjoining room. A side register (SOR-10) can also be installed on the unit if it is installed flush to a wall.
 
Gas heaters are more cost efficient than electric heaters. A sealed combustion chamber helps maintain the indoor air quality. This counterflow furnace has easily removable front panels for maintenance and cleaning. The FAW Series of B-Vent Counterflow furnaces has a 74% AFUE Efficiency Rating.
 
Note: This item is available in Liquid Propane (FAW-40-IPX-LP) and Natural Gas (FAW-40-IPX-NAT)
 
A licensed gas technician is required for installation of this product. Please check your local regulations as some areas may require inspection after installation of gas products. It is highly recommended that you use your own gas technician or gas provider for any repairs. Empire Comfort System warranty covers parts only, no labor.
 
This item replaces FAW40IP.
FREE SHIPPING ON ALL ORDERS!
Empire Comfort Systems FAW-40-IPX 40,000 BTU Counterflow Vented Wall Furnace
  • Empire Comfort Systems FAW-40-IPX 40,000 BTU Counterflow Vented Wall Furnace
  • Empire Comfort Systems FAW-40-IPX 40,000 BTU Counterflow Vented Wall Furnace

Product Overview

Interior or exterior wall installation for the FAW40IPX wall furnace are both possible. Venting of this unit is up and through the roof. Interior installation options include flush on the wall or recessed between standard wall studs.
 
The FAW-40-IPX has an electronic ignition. A thermostat is not included with this furnace. This is a 24V furnace and can be used with either a Wireless Remote Wall Thermostat (TRW) or a Wall Thermostat Millivolt Reed Switch (TMV) [each sold separately].
 
Venting required:
  • Size of Flue Collar: 4" Oval
  • Size of Flue with Oval to Round Adapter: 4" Round
  • Minimum Vent Opening in Ceiling:
    • Oval Type "B" Flue Pipe: 4-1/2" x 9-1/4"
    • Round Type "B" Flue Pipe: 6.5" diameter
Counterflow wall furnaces heat larger areas and use a minimum amount of floor space. Heat comes out at floor level and rises, giving you an even heat distribution. The optional side (SOK-1) and rear (ROK-1) accessory outlet kits allow heat to disperse from side or the rear of the furnace to an adjoining room. A side register (SOR-10) can also be installed on the unit if it is installed flush to a wall.
 
Gas heaters are more cost efficient than electric heaters. A sealed combustion chamber helps maintain the indoor air quality. This counterflow furnace has easily removable front panels for maintenance and cleaning. The FAW Series of B-Vent Counterflow furnaces has a 74% AFUE Efficiency Rating.
 
Note: This item is available in Liquid Propane (FAW-40-IPX-LP) and Natural Gas (FAW-40-IPX-NAT)
 
A licensed gas technician is required for installation of this product. Please check your local regulations as some areas may require inspection after installation of gas products. It is highly recommended that you use your own gas technician or gas provider for any repairs. Empire Comfort System warranty covers parts only, no labor.
 
This item replaces FAW40IP.

Tech Specs

General Features

Installation Type:
Recessed Wall Mount
Fuel Type:
Choice NG / LP
Installation Kit:
Not Included

Performance Data

Heating BTUs:
40000
Heating BTUs (Output):
NA
AFUE Efficiency:
NA

Venting

Type of Venting:
B-Vent
Vent Connection Size (in.):
Oval to 4" Round

System Data

Blower:
Included
Ignition Type:
Electronic Ignition
Control Type:
Wall Thermostat Required (NOT INCLUDED)

Gas Requirements

Gas Connection Size:
1/2"
Manifold Pressure (in.):
4.0" w.c. (NG) / 10.0" w.c. (LP)
Inlet Gas Pressure (Min.):
5.0" w.c. (NG) / 11.0" w.c. (LP)
Inlet Gas Pressure (Max.):
10.5" w.c. (NG) / 13.0" w.c. (LP)

Clearances

Top to Ceiling (in.):
4
Bottom to Floor (in.):
0
To Side Wall (in.):
4

Weights and Dimensions

Width (in.):
14.125
Depth (in.):
10.375
Height (in.):
72.5
Net Weight (lbs.):
110
California residents see Prop 65 WARNINGS

Warning WARNING!

Warning: Cancer and Reproductive Harm - www.p65warnings.ca.gov