null

GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant

Sku:
GE-AVES09DCXXA
Usually Leaves Warehouse in 3 - 5 Business Days
$1,915.00
For your convenience, we are including a Universal Direct Connect Power Supply with this unit. Choose either a 15, 20 or 30 amp hardwire kit.
 
The GE Zoneline Vertical Packaged Terminal Cooling System with Electric Resistive Heat has an EER Rating of 12.0. This GE AVES09DCXXA Zoneline Vertical Air Conditioner or VTAC features offers up to 8,900 BTUs for cooling and electric resistive heat (power supply amperage dependent). The new AVES V10 Series also gives you your choice of power supply. The power amperage you choose is directly related to the amount of electric heat you get. Universal power supply kits are available in 15 Amp; 2.45 kW electric heat, 20 Amp; 3.45 kW electric heat and 30 Amp; 5.0 kW electric heat options. Your choice of power supply is required at purchase. The AVES Series is equipped with 2 fan speeds. 

The GE AVES VTACs now use of R454B refrigerant. R454B features a Global Warming Potential (GWP) of 467 - the most environmentally friendly refrigerant available. The larger the GWP, the more that specific gas warms the Earth. Below is a comparison chart of GWPs now being used by manufacturers versus R410A which is being phased out. 
 
GWP Refrigerant Comparison
 
A GE Vertical Air Conditioner (VTAC or Vertical PTAC) helps you optimize floor space because the unit is concealed in a closet with an outside wall rather than out in the open. With hidden installation, the room becomes more aesthetically appealing, giving it more of an at-home appearance, with no limitations on furniture placement or window treatment installation.

Although the VTAC is still a through-the-wall installation, its footprint is only about 24" x 24" and it is hidden inside an enclosure which looks like a closet, versus a standard PTAC unit which is installed in the room taking up over 42" of floor space. The VTAC uses a wall mounted thermostat and has a top air discharge that can be ducted into one or more rooms - perfect for suite set-ups. The design of the new AVES models includes a one-piece design, which fully integrates with the wall plenum and aligns for a tight seal. This design eliminates the need for building a customized platform on the construction site. Additionally it uses a Quick-Install Plenum that easily installs from inside the building without the need for exterior building access (caulking required).
 
REQUIRED COMPONENTS FOR NEW INSTALLATION (each sold separately):
  • Drain Platform (RAVDPLAT)
  • Plenum or Transition Plenum (RAVWPT15, RAVWPT9, or RAVTRANS2, 3, 4*)
  • Exterior Grille (RAVAL3)
  • Return Air Panel / Access Grille (RAVRG4 / RAVRG2
  • Remote Thermostat (RAK149F2, RAK149P2, RAK180W1)
  • Power Connection Kit - Supplies power to the unit  as well as resistance heat (20 Amp; 3.45 kW - RAK320D, 30 Amp; 5.0 kW - RAK330D). Your choice is included with your purchase.
Electric Heat Data (Power Cord Amp): RAK315D RAK320D RAK330D
Basic Heater Size: 2.45 Kw 3.45 Kw 5.0 Kw
BTUs (@208V):   9629 13952
Heater Watts (@208V): 2004 2822 4089
Heater Amps (@208V):   13.6 19.7
       
BTUs (@230V)   11770 17060
Watts (@230V): 2450 3450 5000
Heating Amps (@230V):   15.0 21.7
Circuit Breaker: 15 20 30
 
Standard features found on the AVES Vertical Air Conditioners include:
  • Insta-Platform – One-piece design fully integrates with the wall plenum and aligns for a tight seal. Eliminates need for a customized platform construction on site
  • Self-Contained Drainage System – Easy installation and simple chassis removal while leaving plumbing completely intact
  • Fast-Connect Plumbing – Thoughtful design enables platform build and rough plumbing completed in only minutes
  • Quick-Install Plenum – Plenum is easily installed from the interior of building, without the need for exterior building access* (*caulking required)
  • Self-aligning, lock in place system proof when the chassis is placed on the platform
  • Onboard Diagnostics – Electronic controls give clear and fast
  • Anti-Corrosion Design – Exclusive rust-proof basepan and bulkhead provide another level of corrosion protection
  • Ultra-Quiet – Delivers quiet cooling power with a smooth sound for a good night’s sleep
  • SmartHQ WIFI capability – An optional WiFi module gives property managers the ability to oversee units, increasing productivity and enhancing guests’ experience
  • Enhanced energy efficiency
  • Sensible Heat Ratio - 73%
  • Central Desk Control Compatibility
  • Corrosion Treated
  • Auto Power Recovery
  • Weather Protected Electrical Components
  • Auto Compressor Random Restart
  • Automatic Emergency Heat
  • Automatic Indoor Frost Control
  • Freeze Sentinel
  • Heat Sentinel
  • Quick Heat Recovery
  • Thermostat Quick Disconnect
  • Boost Heat

*When replacing a previous model GE Vertical Unit with the new AVES Series vertical air conditioner, one of three transition plenums (RAVTRANS2, RAVTRANS3, RAVTRANS4) must be used.

This item replaces the AZ95E09DAC.

Specifications are subject to change.

 

FREE SHIPPING ON ALL ORDERS!
GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • GE AVES09DCXXA 9000 BTU Class Zoneline V10 VTAC with Electric Resistance Heat - Power Connection Kit Included - 208/230 Volt - R454B Refrigerant
  • +9

Product Overview

For your convenience, we are including a Universal Direct Connect Power Supply with this unit. Choose either a 15, 20 or 30 amp hardwire kit.
 
The GE Zoneline Vertical Packaged Terminal Cooling System with Electric Resistive Heat has an EER Rating of 12.0. This GE AVES09DCXXA Zoneline Vertical Air Conditioner or VTAC features offers up to 8,900 BTUs for cooling and electric resistive heat (power supply amperage dependent). The new AVES V10 Series also gives you your choice of power supply. The power amperage you choose is directly related to the amount of electric heat you get. Universal power supply kits are available in 15 Amp; 2.45 kW electric heat, 20 Amp; 3.45 kW electric heat and 30 Amp; 5.0 kW electric heat options. Your choice of power supply is required at purchase. The AVES Series is equipped with 2 fan speeds. 

The GE AVES VTACs now use of R454B refrigerant. R454B features a Global Warming Potential (GWP) of 467 - the most environmentally friendly refrigerant available. The larger the GWP, the more that specific gas warms the Earth. Below is a comparison chart of GWPs now being used by manufacturers versus R410A which is being phased out. 
 
GWP Refrigerant Comparison
 
A GE Vertical Air Conditioner (VTAC or Vertical PTAC) helps you optimize floor space because the unit is concealed in a closet with an outside wall rather than out in the open. With hidden installation, the room becomes more aesthetically appealing, giving it more of an at-home appearance, with no limitations on furniture placement or window treatment installation.

Although the VTAC is still a through-the-wall installation, its footprint is only about 24" x 24" and it is hidden inside an enclosure which looks like a closet, versus a standard PTAC unit which is installed in the room taking up over 42" of floor space. The VTAC uses a wall mounted thermostat and has a top air discharge that can be ducted into one or more rooms - perfect for suite set-ups. The design of the new AVES models includes a one-piece design, which fully integrates with the wall plenum and aligns for a tight seal. This design eliminates the need for building a customized platform on the construction site. Additionally it uses a Quick-Install Plenum that easily installs from inside the building without the need for exterior building access (caulking required).
 
REQUIRED COMPONENTS FOR NEW INSTALLATION (each sold separately):
  • Drain Platform (RAVDPLAT)
  • Plenum or Transition Plenum (RAVWPT15, RAVWPT9, or RAVTRANS2, 3, 4*)
  • Exterior Grille (RAVAL3)
  • Return Air Panel / Access Grille (RAVRG4 / RAVRG2
  • Remote Thermostat (RAK149F2, RAK149P2, RAK180W1)
  • Power Connection Kit - Supplies power to the unit  as well as resistance heat (20 Amp; 3.45 kW - RAK320D, 30 Amp; 5.0 kW - RAK330D). Your choice is included with your purchase.
Electric Heat Data (Power Cord Amp): RAK315D RAK320D RAK330D
Basic Heater Size: 2.45 Kw 3.45 Kw 5.0 Kw
BTUs (@208V):   9629 13952
Heater Watts (@208V): 2004 2822 4089
Heater Amps (@208V):   13.6 19.7
       
BTUs (@230V)   11770 17060
Watts (@230V): 2450 3450 5000
Heating Amps (@230V):   15.0 21.7
Circuit Breaker: 15 20 30
 
Standard features found on the AVES Vertical Air Conditioners include:
  • Insta-Platform – One-piece design fully integrates with the wall plenum and aligns for a tight seal. Eliminates need for a customized platform construction on site
  • Self-Contained Drainage System – Easy installation and simple chassis removal while leaving plumbing completely intact
  • Fast-Connect Plumbing – Thoughtful design enables platform build and rough plumbing completed in only minutes
  • Quick-Install Plenum – Plenum is easily installed from the interior of building, without the need for exterior building access* (*caulking required)
  • Self-aligning, lock in place system proof when the chassis is placed on the platform
  • Onboard Diagnostics – Electronic controls give clear and fast
  • Anti-Corrosion Design – Exclusive rust-proof basepan and bulkhead provide another level of corrosion protection
  • Ultra-Quiet – Delivers quiet cooling power with a smooth sound for a good night’s sleep
  • SmartHQ WIFI capability – An optional WiFi module gives property managers the ability to oversee units, increasing productivity and enhancing guests’ experience
  • Enhanced energy efficiency
  • Sensible Heat Ratio - 73%
  • Central Desk Control Compatibility
  • Corrosion Treated
  • Auto Power Recovery
  • Weather Protected Electrical Components
  • Auto Compressor Random Restart
  • Automatic Emergency Heat
  • Automatic Indoor Frost Control
  • Freeze Sentinel
  • Heat Sentinel
  • Quick Heat Recovery
  • Thermostat Quick Disconnect
  • Boost Heat

*When replacing a previous model GE Vertical Unit with the new AVES Series vertical air conditioner, one of three transition plenums (RAVTRANS2, RAVTRANS3, RAVTRANS4) must be used.

This item replaces the AZ95E09DAC.

Specifications are subject to change.

 

Tech Specs

General Features

Refrigerant Type:
R454B
Compressor:
Standard
Energy Star:
No
Dehumidification (pts/hr):
2.2
CFMs (@ 0.1 ESP):
340 / 420
Includes Heat Mode:
Yes
Heat Type:
Electric Resistance Only
Electric Heat kW:
Power Supply Dependent

Performance @230 Volt

Cooling BTUs (@230V):
8900
EER2 (@230V):
12.0
Cooling Amps (@230V):
TBD
Cooling Watts (@230V):
TBD

Features

Vent Location:
Ducted into room
Make-Up Air:
No
Energy Saver Mode:
No
Fan Speeds:
2
Control Type:
Wall Thermostat Required (NOT INCLUDED)
Connectivity:
Optional WiFi Module Available
Fresh Air Intake:
No

Weights and Dimensions

Overall Depth (in.):
24.125
Overall Width (in.):
23.625
Overall Height (in.):
31.875
Weight (lbs.):
116

Electrical Requirements

Voltage:
208-230V
Circuit Breaker Size (Amps):
Power Supply Dependent (15/20/30)

Electric Heat Performance

Electric Heat Performance @208V and 230V:
See Description (Power Supply Dependent)
California residents see Prop 65 WARNINGS

Warning WARNING!

Warning: Cancer and Reproductive Harm - www.p65warnings.ca.gov

Product Warranty

  • Parts Warranty - 5 years
  • Labor Warranty - 1 year
  • Sealed System Warranty - 5 years