Product Overview
- Reduces in-rush current/draw necessary at startup by up to 70%
- Monitors system health including voltage, current, compressor startup and integrity. Upon a fault condition, it will halt operation and initiate a 3 minute anti-short cycle routine while providing diagnostic fault information by means of an LED indicator.
- Prolongs the life of the AC by reducing excess torque, wear and tear
- Helps reduce the noise and flickering that can occur when an AC unit or other large motor starts up. It can also help to prevent the breaker from tripping.
- Built-in self-learning algorithm - ICM870 will learn the characteristics of the motor is it attached to and adjust its settings accordingly
- Over-current protection
- Over/under voltage monitoring
- Built-in start capacitor
- LED fault indicators
- Ultrasonic sealed tamper-proof enclosure
- Installation hardware is included
Input:
- (L1, L2) – 100-240 VAC 50/60Hz
- Over voltage limits: 115 VAC nominal = 140 VAC, 240 VAC nominal = 264 VAC
- Under voltage limits: 115 VAC nominal = 95 VAC, 240 VAC nominal =195 VAC
Outputs:
- Compressor
- Solid state/relay
- Current: Max. nominal = 9 FLA for ICM870-9A, 16 FLA for ICM870-16A
- Over current limits: ICM870-9A = 11.25A, ICM870-16A = 20A
To be sure you get the appropriate ICM870 soft start kit for your system, check your AC compressor for the run load amps. This is typically located right on the compressor or in the manual for your system. Below is a quick reference guide. Please confirm your own specific equipment requirements.
ICM870-9A: For use with a Compressor Load Amp Rating (RLA) of up to Maximum of 9A
ICM870-16A: For use with a Compressor Load Amp Rating (RLA) of 9.1-16A Maximum
ICM870-32A: For use with a Compressor Load Amp Rating (RLA) of 16.1-32A Maximum
Air Conditioning & Heat Pump Loads – Average | ||||
Size | BTU | *RLA | ICM870-model | |
1 Ton | 12,000 | 6 | ICM870-9A | |
2 Ton | 24,000 | 12 | ICM870-16A | |
3 Ton | 36,000 | 16 | ICM870-16A | |
4 Ton | 48,000 | 22 | ICM870-32A | |
5 Ton | 60,000 | 26 | ICM870-32A | |
6 Ton | 72,000 | 32 | ICM870-32A |
*This chart is intended as a quick reference only. It reflects the average Single-Phase Air Conditioning and Heat Pump conversions of Tonnage, BTU’s, and RLA. Please refer to your service panel or user manual to determine your equipment’s actual RLA rating before deciding which model ICM870 you need.
Overall, a soft start kit is a great investment for your AC unit. It can help to prolong the life of your unit, reduce noise and flickering, and prevent breaker trips. If you are looking for a way to improve the performance and lifespan of your AC unit, then a soft start kit is a great option.
Tech Specs
Environmental Specifications
Weight and Dimensions
WARNING!
Product Warranty
1 Year Warranty