null

Mars Air Systems STD272-2EEN-OB Standard Series (STD2) Heated Air Curtain - 72" - 208 Volt - 3-Phase - Obsidian Black

Sku:
MARS-STD2722EENOB
Usually Leaves Warehouse in 6 to 8 Weeks
$4,425.00

The Standard Series (STD2) of Mars Air Doors offers a variety of lengths to provide an environmental barrier to your space of up to 12 feet, while protecting your space from insects up to 10 feet. The STD2 has a stronger motor and is a little louder than the LoPro (LPV2) series, but its 1/2 horsepower motor may be better suited for your space.

This heated, 208 Volt, 3-phase air curtain is 10 5/8" tall. It comes in a variety of lengths from 36" to 96". The STD272-2EEN-OB is 72" long and includes two 1/2 HP motors. Some sample installation applications include shipping/receiving doors, customer entrances, cold storage rooms and many more. Ideal installation heights is 8' - 12' for the STD2 series. The STD2 Heated Air Curtain features an internal mounted control panel, remote thermostat with heat/off/fan settings.

The STD2 air curtain offers a cost efficient barrier that will blend in to any environment. Its durable metal construction is finished in a powder-coated obsidian black. Units 36" to 48" long feature a single motor, while units 60" to 96" feature a 2- motor design. Each motor boasts 1/2 horsepower. The Standard Series each ship as a single unit, regardless of length.

The profile of the STD2 is low profile for its power.

Profile of STANDARD 2 HEATED Air Curtain

The chart below lays out all the optional lengths available for the STD2 208/3/60 air curtain. The highlighted row is specific to this item. Simply choose your length based on your installation needs. 

It is recommended that a door switch be used with the air curtain. Door limit switches automatically activate and de-activate (start and stop) the air curtain when the door(s) open and close. A controller that offers time delayed control reduces the cycling of the air curtain motors in high traffic areas (10+ times/hour). This type of controller will delay the unit from turning off when the door closes. They can usually be set from 6 seconds to up to 20 minutes. Available door switches and controllers for the STD2, 208 and 230V units include:

  • Door Limit Switch 99-014 - Combination mechanical switch, 250v, 1HP Max
  • Door Limit Switch 99-018 - Commercial Surface mounted, magnetic switch, 24v
  • Controller J0022 - Commercial low voltage controller, 208-277V, 1Ø, adjustable time delay, with commercial plastic surface mounted door limit switch (field installed)

When you add a door switch, your unit will automatically turn on when the door opens and off when it closes. Plus, it will continue running for a configurable period of time.

ModelOverall
Length
(in.)
Motors/HP kW Full Load
Amps
Volume
(CFMs)
Uniformity
(%)
Power
Rating
(Watts)
Weight
3-PHASE                
STD236-1EEH-OB 36" 1 Motor; 1/2 HP 12 36 amps 1379 CFM

84

500

90 lbs
STD242-1EEH-OB 42" 1 Motor; 1/2 HP 12 36 amps 1418 CFM 87 510 95 lbs
STD248-1EEH-OB 48" 1 Motor; 1/2 HP 12 36 amps 1442 CFM 85 550 100 lbs
STD260-2EEN-OB 60" 2 Motors; 1/2 HP each 24 72 amps 2700 CFM 93 940 130 lbs
STD272-2EEN-OB 72" 2 Motors; 1/2 HP each 24 72 amps 2758 CFM 84 1000 180 lbs
STD284-2EEN-OB 84" 2 Motors; 1/2 HP each 24 72 amps 2836 CFM 87 1020 190 lbs
STD296-2EEN-OB 96" 2 Motors; 1/2 HP each 24 72 amps 2884 CFM 85 1100 225 lbs
 
FREE SHIPPING ON ALL ORDERS!
Mars Air Systems Standard Series (STD2) Heated Air Curtain 208/3/60

Product Overview

The Standard Series (STD2) of Mars Air Doors offers a variety of lengths to provide an environmental barrier to your space of up to 12 feet, while protecting your space from insects up to 10 feet. The STD2 has a stronger motor and is a little louder than the LoPro (LPV2) series, but its 1/2 horsepower motor may be better suited for your space.

This heated, 208 Volt, 3-phase air curtain is 10 5/8" tall. It comes in a variety of lengths from 36" to 96". The STD272-2EEN-OB is 72" long and includes two 1/2 HP motors. Some sample installation applications include shipping/receiving doors, customer entrances, cold storage rooms and many more. Ideal installation heights is 8' - 12' for the STD2 series. The STD2 Heated Air Curtain features an internal mounted control panel, remote thermostat with heat/off/fan settings.

The STD2 air curtain offers a cost efficient barrier that will blend in to any environment. Its durable metal construction is finished in a powder-coated obsidian black. Units 36" to 48" long feature a single motor, while units 60" to 96" feature a 2- motor design. Each motor boasts 1/2 horsepower. The Standard Series each ship as a single unit, regardless of length.

The profile of the STD2 is low profile for its power.

Profile of STANDARD 2 HEATED Air Curtain

The chart below lays out all the optional lengths available for the STD2 208/3/60 air curtain. The highlighted row is specific to this item. Simply choose your length based on your installation needs. 

It is recommended that a door switch be used with the air curtain. Door limit switches automatically activate and de-activate (start and stop) the air curtain when the door(s) open and close. A controller that offers time delayed control reduces the cycling of the air curtain motors in high traffic areas (10+ times/hour). This type of controller will delay the unit from turning off when the door closes. They can usually be set from 6 seconds to up to 20 minutes. Available door switches and controllers for the STD2, 208 and 230V units include:

  • Door Limit Switch 99-014 - Combination mechanical switch, 250v, 1HP Max
  • Door Limit Switch 99-018 - Commercial Surface mounted, magnetic switch, 24v
  • Controller J0022 - Commercial low voltage controller, 208-277V, 1Ø, adjustable time delay, with commercial plastic surface mounted door limit switch (field installed)

When you add a door switch, your unit will automatically turn on when the door opens and off when it closes. Plus, it will continue running for a configurable period of time.

ModelOverall
Length
(in.)
Motors/HP kW Full Load
Amps
Volume
(CFMs)
Uniformity
(%)
Power
Rating
(Watts)
Weight
3-PHASE                
STD236-1EEH-OB 36" 1 Motor; 1/2 HP 12 36 amps 1379 CFM

84

500

90 lbs
STD242-1EEH-OB 42" 1 Motor; 1/2 HP 12 36 amps 1418 CFM 87 510 95 lbs
STD248-1EEH-OB 48" 1 Motor; 1/2 HP 12 36 amps 1442 CFM 85 550 100 lbs
STD260-2EEN-OB 60" 2 Motors; 1/2 HP each 24 72 amps 2700 CFM 93 940 130 lbs
STD272-2EEN-OB 72" 2 Motors; 1/2 HP each 24 72 amps 2758 CFM 84 1000 180 lbs
STD284-2EEN-OB 84" 2 Motors; 1/2 HP each 24 72 amps 2836 CFM 87 1020 190 lbs
STD296-2EEN-OB 96" 2 Motors; 1/2 HP each 24 72 amps 2884 CFM 85 1100 225 lbs
 

Tech Specs

Max. Door/Window Height (ft.):
12
Max. Height Insect Block (ft.):
8
Heat:
Yes
Horsepower:
1/2 (per motor)
Voltage:
208V
Phase:
3-Phase
Depth (in.):
17.375
Height (in.):
10.625
Length (in.):
72
Certifications:
ETL Listed
Parts Warranty:
18 Months
Product Type:
Heated
California residents see Prop 65 WARNINGS

Warning WARNING!

Warning: Cancer and Reproductive Harm - www.p65warnings.ca.gov