Reznor 201160 High Altitude Pressure Switch For Reznor UDX/UDZ/UBX/UBZ200, 225; UDX/UBX/UBZ250, 300; UDX/UBX350, 400

Sku:
REZNOR-201160
Usually Leaves Warehouse in 2 - 3 Business Days
$79.00
When installing your Reznor heater above 6000 feet (1830 meters), a change in pressure switches is required. The high altitude pressure switch 201160 is used with several Reznor heaters. Pressure switches are specific to Reznor heaters.  Its brown label indicates the 1.0"w.c.
 
The 201160 Pressure Switch is the appropriate kit required for high altitude installation of the following Reznor Heaters:
  • UDX200
  • UDX225
  • UDX250
  • UDX300
  • UDX350
  • UDX400
  • UDZ200
  • UDZ225
  • UDZ250
  • UBX200
  • UBX225
  • UBX250
  • UBX300
  • UBX350
  • UBX400
  • UBZ200
  • UBZ225
  • UBZ250
  • UBZ300

It can also be used with:

  • UDAP200, UDAP225, UDAP250, UDAP300 (UDAP350, UDAP400 manufactured after 7/23/09)
  • UDAS200, UDAS225, UDAS250, UDAS300 (UDAS350, UDAS400 manufactured after 7/23/09)
  • UDBP200, UDBP225, UDBP250, UDBP300 (UDBP350, UDBP400 manufactured after 7/23/09)
  • UDBS200, UDBS225, UDBS250, UDBS300 (UDBS350, UDBS400 manufactured after 7/23/09)
Please note if you are installing your Reznor Heater above 2000 feet the input rate must be derated. This is done simply by adjusting the valve outlet (see installation manual). You do not need to install anything further.
 
ITEM APPEARANCE MAY DIFFER FROM PHOTO ABOVE
FREE SHIPPING ON ALL ORDERS!
Reznor 201160 High Altitude Pressure Switch For Reznor UDX/UDZ/UBX/UBZ200, 225; UDX/UBX/UBZ250, 300; UDX/UBX350, 400

Product Overview

When installing your Reznor heater above 6000 feet (1830 meters), a change in pressure switches is required. The high altitude pressure switch 201160 is used with several Reznor heaters. Pressure switches are specific to Reznor heaters.  Its brown label indicates the 1.0"w.c.
 
The 201160 Pressure Switch is the appropriate kit required for high altitude installation of the following Reznor Heaters:
  • UDX200
  • UDX225
  • UDX250
  • UDX300
  • UDX350
  • UDX400
  • UDZ200
  • UDZ225
  • UDZ250
  • UBX200
  • UBX225
  • UBX250
  • UBX300
  • UBX350
  • UBX400
  • UBZ200
  • UBZ225
  • UBZ250
  • UBZ300

It can also be used with:

  • UDAP200, UDAP225, UDAP250, UDAP300 (UDAP350, UDAP400 manufactured after 7/23/09)
  • UDAS200, UDAS225, UDAS250, UDAS300 (UDAS350, UDAS400 manufactured after 7/23/09)
  • UDBP200, UDBP225, UDBP250, UDBP300 (UDBP350, UDBP400 manufactured after 7/23/09)
  • UDBS200, UDBS225, UDBS250, UDBS300 (UDBS350, UDBS400 manufactured after 7/23/09)
Please note if you are installing your Reznor Heater above 2000 feet the input rate must be derated. This is done simply by adjusting the valve outlet (see installation manual). You do not need to install anything further.
 
ITEM APPEARANCE MAY DIFFER FROM PHOTO ABOVE