For a long time Reznor has been providing the best heaters for a variety of applications. Reznor has improved their already industry leading technologies with the UDXC line of unit heaters. The UDXC is a line of power vented unit heaters that can be field converted to separated combustion. Featuring a new, sleeker design, Reznor units still offer efficiency and easy installation.
 
With an industry leading 82-83% thermal efficiency and a variety of different BTUs, the UDXC series of heaters offer exceptional heat performance for areas both large and small. The 30,000 - 125,000 BTU models are all approved for use in commercial buildings as well as residential garages and workshops. The UDXC150 (150,000 BTU) is ideal for smaller-sized commercial spaces. For larger, commercial spaces, UDXC units come in a variety of BTUs up to 400,000. Please contact us for an estimate of the number of BTUs you need for your location.
 
The defining feature of the UDXC models is their ability to be converted (in the field) from a power-vented unit heater to a separated combustion heater, with the addition of a SC1 kit. When used in a separated combustion installation, the air used for combustion is pulled in from the outside or another room rather than from within the space. This process helps ensure that all air introduced to the inside of the heater is fresh and free of harmful particulates, making these heaters particularly useful in settings where chemicals are stored or frequently used, and/or humidity levels tend to be high. It is also a great choice for dusty environments like wood shops. Concentric Venting (an exhaust terminal and combustion air inlet ) is required for separated combustion use. The CC2 Vertical Vent Kit Package or the CC6 Horizontal Vent Kit Package are available.
 
The UDXC Series heaters are easy to install, secured in place from 2 or 4 suspension points or by an optional Quick-Sling hanger kit that allows for ceiling mounting. Thermostat setup is quick, with an external terminal strip connector for 24-volt wiring. The factory installed gas line input is located on the backside of the unit heater making the gas connection simple. Additionally, the UDXC Series has an easily accessible, hinged, service door. With a simple turn of a screwdriver the door swings open (includes a safety strap) or can be easily removed for service in tight spaces. Alphanumeric digital display of error codes along with a listing of the fault codes on the door, are easy to see and help the repair tech, ultimately minimizing downtime.
 
The sleek new look of the UDXC Series includes a white cabinet with black powder-coated louvers as well as an angled corner for a more modern look. Of course, you will still find the Reznor Logo emblazoned right on the front of the unit, in addition to the single red louver among the standard black louvers. 
 
Standard features include Reznor’s patented TCore² titanium stabilized aluminized steel heat exchanger, as well as the  "G" terminal to the strip and a newly designed circuit board, which allows for fan-only operation without adding relays. Outwardly, Reznor has developed a sleeker design that shows no front or bottom hardware. 

Optional Accessories

SC1 Separated Combustion Kit - Converts your UDXC to a separated combustion unit. The kit includes door seal, door switch, vent adapter gasket, and collar for the combustion of air inlet of unit. CC2 Vertical OR CC6 Horizontal Vent Kit is required. If the CC2 or CC6 Vent Kit is not installed in a separated combustion installation, your manufacturer warranty will be void. The SC1 kit is specific to the BTUs of your unit. We have included the appropriate SC1 kit with your choice of CC6 horizontal or CC2 vertical venting above. 
 
The most popular optional accessories (shown in the add to cart box at the top of the page) are available with this unit. Please visit the links below to see the full descriptions for each of these items. Optional accessories should be added to the cart on this page when placing your order.
 
For use in a Power Vent Installation:

For Use in a Separated Combustion Installation:

  • Horizontal Vent Kit - Includes the CC6 horizontal vent kit and SC1 Separated Combustion Kit for UDXC150. Vent pipe not included. 
  • Vertical Vent Kit - - Includes the CC2 vertical vent kit and SC1 Separated Combustion Kit for UDXC150. Vent pipe not included.

For use with any installation:

  • LP Conversion Kit
  • Mounting Bracket 
  • DOWNTURN NOZZLES - Several downturn nozzles are available, including two separate angled options. The CD2 and CD4 feature a downturn of 25 - 65° and are available with or without a vertical louver kit and the CD3 features a downturn of 50 - 90° - this option is only available without a vertical louver kit.

Features

  • All units (up to 400,000 BTUs) available for commercial/industrial heating application
  • 30,000 - 125,000 BTU certified for residential garage and workshop installations
  • Certified for commercial/industrial heating application
  • 82-83% Thermal efficiency - Best in its class!
  • 50-60°F Temperature Rise range
  • Tcore² titanium stabilized aluminized steel heat exchanger
    • 316 Stainless Steel Heat Exchanger or 409 Stainless Steel Heat Exchanger are available as a Special Order requiring additional Lead Time. Please contact us for pricing and availability details  
  • 115/1/60 Supply voltage
  • External diagnostic LED light
  • Built-in circuit board with easy to read error code segment display
  • Direct spark ignition with cutoff
  • Single or two stage gas valve with external gas service connection
  • Designed for quiet operation with vibration isolated fan and venter motors
  • 2 point or 4 point suspension
  • External terminal strip for 24-volt wiring
  • Built-in disconnect switch
  • Improved cabinet design with less visible hardware

 

This item replaces UDAP-150, UDAS-150, UDX-150 and UDZ-150.

 

FREE SHIPPING ON ALL ORDERS!
Reznor UDXC-150 150,000 BTU Power Vented Gas Fired Unit Heater - Separated Combustion Convertible
Product Video

Product Overview

For a long time Reznor has been providing the best heaters for a variety of applications. Reznor has improved their already industry leading technologies with the UDXC line of unit heaters. The UDXC is a line of power vented unit heaters that can be field converted to separated combustion. Featuring a new, sleeker design, Reznor units still offer efficiency and easy installation.
 
With an industry leading 82-83% thermal efficiency and a variety of different BTUs, the UDXC series of heaters offer exceptional heat performance for areas both large and small. The 30,000 - 125,000 BTU models are all approved for use in commercial buildings as well as residential garages and workshops. The UDXC150 (150,000 BTU) is ideal for smaller-sized commercial spaces. For larger, commercial spaces, UDXC units come in a variety of BTUs up to 400,000. Please contact us for an estimate of the number of BTUs you need for your location.
 
The defining feature of the UDXC models is their ability to be converted (in the field) from a power-vented unit heater to a separated combustion heater, with the addition of a SC1 kit. When used in a separated combustion installation, the air used for combustion is pulled in from the outside or another room rather than from within the space. This process helps ensure that all air introduced to the inside of the heater is fresh and free of harmful particulates, making these heaters particularly useful in settings where chemicals are stored or frequently used, and/or humidity levels tend to be high. It is also a great choice for dusty environments like wood shops. Concentric Venting (an exhaust terminal and combustion air inlet ) is required for separated combustion use. The CC2 Vertical Vent Kit Package or the CC6 Horizontal Vent Kit Package are available.
 
The UDXC Series heaters are easy to install, secured in place from 2 or 4 suspension points or by an optional Quick-Sling hanger kit that allows for ceiling mounting. Thermostat setup is quick, with an external terminal strip connector for 24-volt wiring. The factory installed gas line input is located on the backside of the unit heater making the gas connection simple. Additionally, the UDXC Series has an easily accessible, hinged, service door. With a simple turn of a screwdriver the door swings open (includes a safety strap) or can be easily removed for service in tight spaces. Alphanumeric digital display of error codes along with a listing of the fault codes on the door, are easy to see and help the repair tech, ultimately minimizing downtime.
 
The sleek new look of the UDXC Series includes a white cabinet with black powder-coated louvers as well as an angled corner for a more modern look. Of course, you will still find the Reznor Logo emblazoned right on the front of the unit, in addition to the single red louver among the standard black louvers. 
 
Standard features include Reznor’s patented TCore² titanium stabilized aluminized steel heat exchanger, as well as the  "G" terminal to the strip and a newly designed circuit board, which allows for fan-only operation without adding relays. Outwardly, Reznor has developed a sleeker design that shows no front or bottom hardware. 

Optional Accessories

SC1 Separated Combustion Kit - Converts your UDXC to a separated combustion unit. The kit includes door seal, door switch, vent adapter gasket, and collar for the combustion of air inlet of unit. CC2 Vertical OR CC6 Horizontal Vent Kit is required. If the CC2 or CC6 Vent Kit is not installed in a separated combustion installation, your manufacturer warranty will be void. The SC1 kit is specific to the BTUs of your unit. We have included the appropriate SC1 kit with your choice of CC6 horizontal or CC2 vertical venting above. 
 
The most popular optional accessories (shown in the add to cart box at the top of the page) are available with this unit. Please visit the links below to see the full descriptions for each of these items. Optional accessories should be added to the cart on this page when placing your order.
 
For use in a Power Vent Installation:

For Use in a Separated Combustion Installation:

  • Horizontal Vent Kit - Includes the CC6 horizontal vent kit and SC1 Separated Combustion Kit for UDXC150. Vent pipe not included. 
  • Vertical Vent Kit - - Includes the CC2 vertical vent kit and SC1 Separated Combustion Kit for UDXC150. Vent pipe not included.

For use with any installation:

  • LP Conversion Kit
  • Mounting Bracket 
  • DOWNTURN NOZZLES - Several downturn nozzles are available, including two separate angled options. The CD2 and CD4 feature a downturn of 25 - 65° and are available with or without a vertical louver kit and the CD3 features a downturn of 50 - 90° - this option is only available without a vertical louver kit.

Features

  • All units (up to 400,000 BTUs) available for commercial/industrial heating application
  • 30,000 - 125,000 BTU certified for residential garage and workshop installations
  • Certified for commercial/industrial heating application
  • 82-83% Thermal efficiency - Best in its class!
  • 50-60°F Temperature Rise range
  • Tcore² titanium stabilized aluminized steel heat exchanger
    • 316 Stainless Steel Heat Exchanger or 409 Stainless Steel Heat Exchanger are available as a Special Order requiring additional Lead Time. Please contact us for pricing and availability details  
  • 115/1/60 Supply voltage
  • External diagnostic LED light
  • Built-in circuit board with easy to read error code segment display
  • Direct spark ignition with cutoff
  • Single or two stage gas valve with external gas service connection
  • Designed for quiet operation with vibration isolated fan and venter motors
  • 2 point or 4 point suspension
  • External terminal strip for 24-volt wiring
  • Built-in disconnect switch
  • Improved cabinet design with less visible hardware

 

This item replaces UDAP-150, UDAS-150, UDX-150 and UDZ-150.

 

Tech Specs

General Features

Installation Type:
Ceiling Mount
Fuel Type:
Natural Gas (NG)
Certified Usage:
Commercial (Indoor Only)
Separated Combustion Chamber:
No

Performance

Heating BTUs (Input):
150000
Heating BTUs (Output):
87150 / 124500 (L / H)

System Data

Noise Level (dBA):
51
Thermal Efficiency:
83%
CFMs:
1921
Output Velocity (FPMs):
752
Discharge Air Temperature Rise (°F):
60
Discharge Air Opening Area (ft²):
2.56

Connections

Gas Connection Size:
1/2"
Vent Connection Size (in.):
5"

Clearances

Top to Ceiling (in.):
4"
Bottom to Floor (ft.):
5'
To Side Wall (in.):
2"
To Rear Wall (in.):
18"
Access Panel (in.):
18"
Flue / Vent Connector (in.):
6"

Weights and Dimensions

Width (in.):
38.188
Depth (in.):
48.438
Height (in.):
20.125
Net Weight (lbs.):
178

Electrical Requirements

Voltage:
110-120V
Amps:
3.8
Normal Watts Consumption:
392
Circuit Breaker Size (Amps):
15
California residents see Prop 65 WARNINGS

Warning WARNING!

Warning: Cancer and Reproductive Harm - www.p65warnings.ca.gov

Product Warranty

1 Year Parts Warranty

Extended nine (9)-year, non-prorated warranty on the heat exchanger, burners, and flue collection box assembly.

Extended four (4)-year, non-prorated warranty on all electrical and mechanical operating components