$990.90
Burners are certified to work with SPECIFIC Log Sets only. While there may be several allowable Log Sets for a specific burner, they are NOT universal. Using a burner with a non-compatible log set can lead to Fire, Carbon Monoxide Poisoning and Property Damage.
When choosing a G46 burner, the pilot kit is factory installed and the burner is ANSI certified. All burners use the same grate (included).

The G46 burner is Triple T burner and features an advanced glowing ember burner system. It includes pre-installed valve/controls with remote control system. The tapered shape of the G46 burner allows attachment of the pilot kit to the angled side of the burner rather than the end, reducing the clearance by more than half, compared to other burners.
 
The G46 burner consists of a main burner tube that extends down the middle and a smaller front flame burner that "T"s off the main burner. The additional front flame allows you to position the burner directly beneath the logs helping to accentuate the front flame. This specialized burner also gives you a nice bed of glowing embers under beautiful dancing flames. With its front pipe, there are three additional spaces for the flames to come through, adding more depth to your fire. Its angled sides and required minimum firebox dimensions may allow for a larger log set in your fireplace and the burner offers more lively, realistic looking flames and glowing embers. Log Set sold separately.
 
The G46 Burner system includes:
  • ANSI Certified Burner
  • Pre-assembled control valve and regulator - APK-17 variable flame, remote safety valve
  • Piezo Ignitor
  • Grate
  • Glowing embers
  • Sand
  • Connector kit
  • Log locators
  • Damper clamp
The APK-17 is a variable flame remote control safety pilot system which features a Low profile adjustable flame remote control safety pilot that takes up less room and requires less clearance inside your fireplace. It uses a standing pilot that stays lit. As long as the safety pilot is lit, the burner can be turned on or off and the flame height can be adjusted by remote or manually. The APK-17 includes VR-1 On/Off remote transmitter that actually adjusts the flame height as well.
 
You can upgrade to VR-2 Deluxe Remote Control system with Thermostat, Timer, Clock and Room Temperature (sold separately).
 
Log set sold separately.
 
Burner ModelMinimum Fireplace SizeBTU Ratings
Width*DepthHeightNGLP
FrontRear
G46-18/20  26" 20" 15" 17" 40k 40k
G46-24  30" 24" 15" 17" 55K 55k
G46-30  35" 29" 15" 17" 65k 65k
       
*The required widths allow for centering of the unit within the fireplace. For G46-**-02 models, add 6" to the front width and 4" to the rear width. Depth requirements begin inside the ash lip if one exists.
FREE SHIPPING ON ALL ORDERS!
RH Peterson Real-Fyre G462417N 24" ANSI Certified Triple T Vented Burner with Automatic Pilot / Variable Flame - Natural Gas
  • RH Peterson Real-Fyre G462417N 24" ANSI Certified Triple T Vented Burner with Automatic Pilot / Variable Flame - Natural Gas
  • RH Peterson Real-Fyre G462417N 24" ANSI Certified Triple T Vented Burner with Automatic Pilot / Variable Flame - Natural Gas
  • RH Peterson Real-Fyre G462417N 24" ANSI Certified Triple T Vented Burner with Automatic Pilot / Variable Flame - Natural Gas

Product Overview

Burners are certified to work with SPECIFIC Log Sets only. While there may be several allowable Log Sets for a specific burner, they are NOT universal. Using a burner with a non-compatible log set can lead to Fire, Carbon Monoxide Poisoning and Property Damage.
When choosing a G46 burner, the pilot kit is factory installed and the burner is ANSI certified. All burners use the same grate (included).

The G46 burner is Triple T burner and features an advanced glowing ember burner system. It includes pre-installed valve/controls with remote control system. The tapered shape of the G46 burner allows attachment of the pilot kit to the angled side of the burner rather than the end, reducing the clearance by more than half, compared to other burners.
 
The G46 burner consists of a main burner tube that extends down the middle and a smaller front flame burner that "T"s off the main burner. The additional front flame allows you to position the burner directly beneath the logs helping to accentuate the front flame. This specialized burner also gives you a nice bed of glowing embers under beautiful dancing flames. With its front pipe, there are three additional spaces for the flames to come through, adding more depth to your fire. Its angled sides and required minimum firebox dimensions may allow for a larger log set in your fireplace and the burner offers more lively, realistic looking flames and glowing embers. Log Set sold separately.
 
The G46 Burner system includes:
  • ANSI Certified Burner
  • Pre-assembled control valve and regulator - APK-17 variable flame, remote safety valve
  • Piezo Ignitor
  • Grate
  • Glowing embers
  • Sand
  • Connector kit
  • Log locators
  • Damper clamp
The APK-17 is a variable flame remote control safety pilot system which features a Low profile adjustable flame remote control safety pilot that takes up less room and requires less clearance inside your fireplace. It uses a standing pilot that stays lit. As long as the safety pilot is lit, the burner can be turned on or off and the flame height can be adjusted by remote or manually. The APK-17 includes VR-1 On/Off remote transmitter that actually adjusts the flame height as well.
 
You can upgrade to VR-2 Deluxe Remote Control system with Thermostat, Timer, Clock and Room Temperature (sold separately).
 
Log set sold separately.
 
Burner ModelMinimum Fireplace SizeBTU Ratings
Width*DepthHeightNGLP
FrontRear
G46-18/20  26" 20" 15" 17" 40k 40k
G46-24  30" 24" 15" 17" 55K 55k
G46-30  35" 29" 15" 17" 65k 65k
       
*The required widths allow for centering of the unit within the fireplace. For G46-**-02 models, add 6" to the front width and 4" to the rear width. Depth requirements begin inside the ash lip if one exists.

Tech Specs

General Features

Fireplace Style:
Single Sided
Location of Use:
Indoor
Type of Venting:
Vented
Media Style:
Traditional Log Set
Type of Grate:
Standard
Fuel Type:
Natural Gas (NG)
Allowable Log Set Sizes (in.):
24"
Allowable Log Sets:
Real-Fyre Gas Log Set Not Included
Certified Usage:
Mobile Home Approved

Performance

BTUs (Max.):
55000
Ignition Type:
Electronic Ignition
Remote:
Variable Flame Remote Included

Gas Requirements

Gas Connection Size (in.):
1/2"
Manifold Pressure (in.):
NA
Inlet Gas Pressure (Min.):
5.0" w.c.
Inlet Gas Pressure (Max.):
10.5" w.c.

Minimum Firebox Requirements

Requirements for 24" Logs

Req. Min. Front Width (in.):
30"
Req. Min. Rear Width (in.):
24"
Req. Min. Depth (in.):
15"
Req. Min. Height (in.):
17"
Chimney Height (Min. ft.):
15'