Product Overview
Burner Options
G-45 Burner
The G-45 Burner features a double pipe design also referred to as a Triple T Burner. It includes the main burner tube in the middle plus a smaller front flame burner that "T"s off the main burner. This gives you three additional spaces for the flames to come through, adding more depth to your fire. With this burner you get a nice bed of glowing embers under beautiful dancing flames. We offer it with a Manual SPK-26 Safety Valve, Variable Flame On/Off Remote with Standing Pilot APK-17 Valve, On/Off Remote with Standing Pilot APK-11 Valve, and Electronic Ignition with On/Off Remote EPK-2 Valve.
Valve Options
SPK-26
Low profile Manual Control valve features a standing pilot and includes basic on/off operation with a control knob. A heat shield is included. A remote cannot be used with this valve.
APK-17
Variable flame remote control safety pilot system with standing pilot. It features a low profile adjustable flame remote control. As long as the safety pilot is lit, the burner can be turned on or off and the flame height can be adjusted by remote, wall switch or manually. It includes VR-1 On/Off remote transmitter that actually adjusts the flame height as well.
APK-11
Basic on/off remote safety pilot kit with standing pilot. As long as the safety pilot is lit, the burner can be turned on / off from the remote control, wall switch or manually with an on/off control inside the fireplace. Flame height with this valve is constant, not variable. The APK-11 includes a basic RR-1 On/Off remote control transmitter and receiver.
EPK-2
Low Profile Electronic Ignition Pilotless Remote Control Safety Valve system. It uses the latest technology with an energy saving automatic electronic ignition system and does NOT have a standing pilot. This system includes a basic RR-1 On/Off remote control transmitter and receiver. Can be operated with the remote control, a wall switch or manually with an on/off control inside the fireplace.
GX45 Burner Models with Heavy Duty Grate (Manual Burners include a Safety Pilot Kit - SPK-26) | Minimum Fireplace Size | BTU Ratings | ||||
---|---|---|---|---|---|---|
Width* | Depth | Height | NG | LP | ||
Front | Rear | |||||
18" Vented Burners | ||||||
G-45 Triple T Burner |
30" | 24" | 13" | 17" | 70k | 45k |
24" Vented Burners | ||||||
G-45 Triple T Burner | 34" | 28" | 13" | 17" | 90k | 65k |
30" Vented Burners | ||||||
G-45 Triple T Burner | 40" | 34" | 16" | 17" | 95k | 75k |
*The required widths allow for centering of the unit within the fireplace. For G45-**-02 models (electronic ignition), add 2" to both the front and rear width. Depth requirements begin inside the ash lip if one exists. |