Williams Furnace Company 3005622 30000 BTU Floor Furnace

Sku:
WILLIAMS-FURNACE-3005622
Usually Leaves Warehouse in 3 - 5 Business Days
$1,999.00
Whether it's for a remodel, new construction, or any place where space is limited, the Williams Floor Furnace efficiently warms the room without the need of a blower. Designed for low fuel consumption, these floor furnaces are fitted with a floor-register grille and non-electric pilot, allowing for continuous heat, even during a power outage. Easy installation and easy-to-get-to combustion chamber make servicing no problem at all. It uses a millivolt wall thermostat. Several are available and all sold separately.
 
This newly remodeled floor furnace is available in Natural Gas only. A conversion kit (49200) is available separately for converting to liquid propane. Please select your options such as a high elevation kit (if you are 2001 ft. or more above sea level), and a thermostat at the time of purchase.
 
The 3005622 provides 30,000 BTUs of heat from the floor up! It features a narrow width of only 14", requiring a smaller floor opening of 14-1/2" wide x 32.25" long. The heavy-duty steel, baked enamel floor grill is 16" x 34-1/8" and will blend with hardwood, carpet or tile.
  • No electricity required
  • Matchless pilot ignition
  • Continuous-seam welded combustion chamber
  • Inner jacket suspended with easily removable "U" type interlocking brackets
  • Jet-tube burners
  • Long-life and quiet, heavy-duty burner
  • Convertible gas valves
  • Meets the latest American National Standards Institute Requirements
 
Professional installation by a certified gas technician is required for this item. It is highly recommended that you use your own gas technician or gas provider for any repairs.
 
WILLIAMS NO LONGER OFFERS FACTORY INSTALLED HIGH ELEVATION KITS. Williams furnaces come factory set for elevations up to 2000 feet above sea level. A high elevation kit (49800) is sold separately.
 
 
FREE SHIPPING ON ALL ORDERS!
Williams Furnace Company 300562 30000 BTU Floor Furnace
  • Williams Furnace Company 300562 30000 BTU Floor Furnace
  • Williams Furnace Company 3005622 30000 BTU Floor Furnace

Product Overview

Whether it's for a remodel, new construction, or any place where space is limited, the Williams Floor Furnace efficiently warms the room without the need of a blower. Designed for low fuel consumption, these floor furnaces are fitted with a floor-register grille and non-electric pilot, allowing for continuous heat, even during a power outage. Easy installation and easy-to-get-to combustion chamber make servicing no problem at all. It uses a millivolt wall thermostat. Several are available and all sold separately.
 
This newly remodeled floor furnace is available in Natural Gas only. A conversion kit (49200) is available separately for converting to liquid propane. Please select your options such as a high elevation kit (if you are 2001 ft. or more above sea level), and a thermostat at the time of purchase.
 
The 3005622 provides 30,000 BTUs of heat from the floor up! It features a narrow width of only 14", requiring a smaller floor opening of 14-1/2" wide x 32.25" long. The heavy-duty steel, baked enamel floor grill is 16" x 34-1/8" and will blend with hardwood, carpet or tile.
  • No electricity required
  • Matchless pilot ignition
  • Continuous-seam welded combustion chamber
  • Inner jacket suspended with easily removable "U" type interlocking brackets
  • Jet-tube burners
  • Long-life and quiet, heavy-duty burner
  • Convertible gas valves
  • Meets the latest American National Standards Institute Requirements
 
Professional installation by a certified gas technician is required for this item. It is highly recommended that you use your own gas technician or gas provider for any repairs.
 
WILLIAMS NO LONGER OFFERS FACTORY INSTALLED HIGH ELEVATION KITS. Williams furnaces come factory set for elevations up to 2000 feet above sea level. A high elevation kit (49800) is sold separately.
 
 

Tech Specs

General Features

Installation Type:
Floor
Fuel Type:
Natural Gas (NG)
Installation Kit:
Not Included

Performance Data

Heating BTUs:
30000
Heating BTUs (Output):
21000
AFUE Efficiency:
57%
Thermal Efficiency:
70%

Venting

Type of Venting:
B-Vent
Vent Connection Size (in.):
4

System Data

Blower:
Not Available
Ignition Type:
Standing Pilot
Control Type:
Wall Thermostat Required (NOT INCLUDED)

Gas Requirements

Gas Connection Size:
1/2"
Manifold Pressure (in.):
4.0" w.c.
Inlet Gas Pressure (Min.):
5.0" w.c.
Inlet Gas Pressure (Max.):
7.0" w.c.

Clearances

Center of Vent to Floor (in.):
22
To Side Wall (in.):
8
To Ground Level (in.):
6

Weights and Dimensions

Width (in.):
14
Length (in.):
32
Height (in.):
29.25
Net Weight (lbs.):
110
Certifications:
CSA
California residents see Prop 65 WARNINGS

Warning WARNING!

Warning: Cancer and Reproductive Harm - www.p65warnings.ca.gov

Product Warranty

Parts Warranty: Limited 1 Year; Combustion Chamber Warranty: 10 Year